Update Simple Example to Version 3.2
Description
The following issues have been found so far:
-
The switch "69W04" is located on netElement "ne_b02". It "functions" as switch (with choice of way) for trains that pass this netElement in reverse direction. Therefore, applicationDirection of the switch element "69W04" need to be corrected from "normal" to "reverse".
-
The switches "69W03" and "60W04" have linear coordinates given in kilometer values ("4.500"). The used linearPositioningSystem defines the units to be meters. Therefore, the location measure values of switches "69W03" and "69W04" need to be corrected from km to m ("4.500" --> "4500.0").
Background
Simple Example can be downloaded from railML Website: [https://www.railml.org/en/user/exampledata.html]
Links
- Forum discussion
- Peter Vancsa, 26.06.2020: [https://www.railml.org/forum/index.php?t=msg&th=738&start=0&]
- Trac tickets
- Wiki documentation
Proposed solution
Attribute @applicationDirection of the switch element "69W04" need to be corrected from "normal" to "reverse" in Simple Example railML 3.1 export file.
Attribute @measure of the switch element "69W03" need to be corrected from "4.500" to "4500.0". Attribute @measure of the switch element "69W04" need to be corrected from "4.550" to "4550.0".